Model | SUN-30K-G04 | SUN-33K-G04 | SUN-35K-G04 | SUN-36K-G04 |
PV String Input Date | ||||
Max. PV Input Power(kW) | 39 | 42.9 | 45.5 | 46.8 |
Max. PV Input Voltage(V) | 1000 | |||
Start-up Voltage(V) | 250 | |||
MPPT voltage range(V) | 200-850 | |||
Rated PV Input voltage(V) | 600 | |||
Max. Input Short Circuit Current (A) | 60+60 | |||
Max. Operating PV Input Current(A) | 40+40 | |||
No. of MPP Trackers/No. of Strings per MPP Tracker | 2/3+3 | |||
AC Input/Output Side | ||||
Rated AC Output Active Power(kW) | 30 | 33 | 35 | 36 |
Max. AC Output Apparent Power(kVA) | 33 | 36.3 | 38.5 | 39.6 |
Rated AC output current (A) | 45.5/43.5 | 50/47.8 | 53/50.7 | 54.5/52.2 |
Max. AC Output Current(A) | 50/47.9 | 55/52.6 | 58.3/55.8 | 60/57.4 |
Rated output voltage/range (V) | 220/380V, 230/400V 0.85Un-1.1Un | |||
Grid Connection Form | 3L/N/PE | |||
Rated Output Grid Frequency/range(Hz) | 50/45-55, 60/55-65 | |||
Power Factor Adjustment Range | 0.8 leading to 0.8lagging | |||
Total Current Harmonic Distortion THDi | <3% | |||
DC Injection Current | <0.5%ln | |||
Efficiency | ||||
Max. Efficiency | 98.6% | |||
Euro Efficiency | 98.1% | |||
MPPT Efficiency | >99% | |||
Equipment Protection | ||||
DC Polarity Reverse Connection Protection | yes | |||
AC Output Overcurrent Protection | yes | |||
AC Output Overvoltage Protection | yes | |||
AC Output Short Circuit Protection | yes | |||
Thermal Protection | yes | |||
DC Terminal Insulation Impedance Monitoring | yes | |||
DC Component Monitoring | yes | |||
Ground Fault Current Monitoring | yes | |||
Power Network Monitoring | yes | |||
Island Protection Monitoring | yes | |||
Earth Fault Detection | yes | |||
DC Input Switch | yes | |||
Overvoltage Load Drop Protection | yes | |||
Residual Current (RCD) Detection | yes | |||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||
Interface | ||||
Communication Interface | RS485/RS232 /WiFi/LAN | |||
General Data | ||||
Operating Temperature Range (°C) | -25 to +60℃, >45℃ Derating | |||
Permissible Ambient Humidity | 0~100% | |||
Permissible Altitude (m) | 4000m | |||
Noise (dB) | ≤ 50 | |||
Ingress Protection(IP) Rating | IP 65 | |||
Inverter Topology | Non-Isolated | |||
Over Voltage Category | OVC II(DC),OVC III(AC) | |||
Cabinet Size (WxHxD mm) | 362mm*577mm*215mm(Excluding connectors and brackets) | |||
Weight [kg] | 23 | |||
Warranty [year] | 5 years | |||
Type Of Cooling | Intelligent air cooling | |||
Grid Regulation | IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | |||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |