-
127V/220V, 133V/230V and50/60Hz, Three phase system
- 4 MPP tracker, Max. efficiency up to 98.7%
- Zero export application, VSG application
- String intelligent monitoring (optional)
- Wide output voltage range
- Anti-PID function (Optional)
This series inverter is specially designed for 127/220Vac,133/230Vac three-phase system, providing rated power at 33KW, 40KW, 45KW, 50KW. Equipped with large LCD and buttons, easy to operate and maintenance. With compact design and high-power density, this series supports 1.3 DC/AC ratio, saving device investment.
Model | SUN-33K-G-LV | SUN-35K-G-LV | SUN-40K-G-LV | SUN-45K-G-LV | SUN-50K-G-LV |
PV String Input Date | |||||
Max. PV Input Power(kW) | 42.9 | 45.5 | 52 | 58.5 | 65 |
Max. PV Input Voltage(V) | 800 | ||||
Start-up Voltage(V) | 250 | ||||
MPPT voltage range(V) | 200-700 | ||||
Rated PV Input voltage(V) | 400 | ||||
Max. Operating PV Input Current (A) | 40+40+40+40 | ||||
Max. Input Short Circuit Current (A) | 60+60+60+60 | ||||
No. of MPP Trackers/No. of Strings per MPP Tracker | 4/3+3+3+3 | 4/4+4+4+4 | |||
AC Input/Output Side | |||||
Rated AC Output Active Power(kW) | 33 | 35 | 40 | 45 | 50 |
Max. AC Output Apparent Power(kVA) | 33 | 35 | 40 | 45 | 50 |
Rated AC output current (A) | 86.7/82.8 | 91.9/87.8 | 105/100.3 | 118.2/112.8 | 131.3/125.4 |
Max. AC Output Current(A) | 86.7/82.8 | 91.9/87.8 | 105/100.3 | 118.2/112.8 | 131.3/125.4 |
Rated output voltage/range (V) | 127V/220V, 133V/230V 0.85UN-1.1UN | ||||
Grid Connection Form | 3L/N/PE | ||||
Rated Output Grid Frequency/range(Hz) | 50/45-55, 60/55-65 | ||||
Power Factor Adjustment Range | 0.8 leading-0.8lagging | ||||
Total Current Harmonic Distortion THDi | <3% | ||||
DC Injection Current | <0.5%ln | ||||
Efficiency | |||||
Max. Efficiency | 98.7% | ||||
MPPT Efficiency | >99% | ||||
Equipment Protection | |||||
DC Polarity Reverse Connection Protection | yes | ||||
AC Output Overcurrent Protection | yes | ||||
AC Output Overvoltage Protection | yes | ||||
AC Output Short Circuit Protection | yes | ||||
Thermal Protection | yes | ||||
DC Terminal Insulation Impedance Monitoring | yes | ||||
DC Component Monitoring | yes | ||||
Ground Fault Current Monitoring | yes | ||||
Power Network Monitoring | yes | ||||
Island Protection Monitoring | yes | ||||
Earth Fault Detection | yes | ||||
DC Input Switch | yes | ||||
Overvoltage Load Drop Protection | yes | ||||
Residual Current (RCD) Detection | yes | ||||
Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||||
Interface | |||||
Communication Interface | RS485/RS232 /WiFi/LAN | ||||
General Data | |||||
Operating Temperature Range (°C) | -25 to +60℃, >45℃ Derating | ||||
Permissible Ambient Humidity | 0~100% | ||||
Permissible Altitude (m) | 2000m | ||||
Noise (dB) | ≤50 dB(A) | ≤55 dB(A) | |||
Ingress Protection(IP) Rating | IP 65 | ||||
Inverter Topology | Non-Isolated | ||||
Over Voltage Category | OVC II(DC),OVC III(AC) | ||||
Cabinet Size (WxHxD mm) | 700×575×297 (Excluding Connectors and Brackets) | ||||
Weight [kg] | 60 | ||||
Warranty [year] | 5 years | ||||
Type Of Cooling | Intelligent Air Cooling | ||||
Grid Regulation | NBR 16149, NBR 16150, EN 50549, RD 140 | ||||
Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |