Model
|
SUN-5K-SG01LP1-US
|
SUN-6K-SG01LP1-US
|
SUN-7.6K-SG01LP1-US
|
SUN-8K-SG01LP1-US
|
Battery Input Data
|
|
Battery Type
|
Lead-acid or Lithium-ion
|
Battery Voltage Range(V)
|
40-60
|
Max.Charging Current(A)
|
120
|
135
|
190
|
190
|
Max.Discharging Current(A)
|
120
|
135
|
190
|
190
|
Charging Strategy for Li-ion Battery
|
Self-adaption to BMS
|
Number of battery input
|
1
|
PV String Input Data
|
|
Max DC Input Power(W)
|
6500
|
7800
|
9880
|
10400
|
Max DC Input Voltage(V)
|
500
|
Start-up Voltage(V)
|
125
|
MPPT Voltage Range(V)
|
150-425
|
Rated DC Input Voltage(V)
|
370
|
Max Input Short-Circuit Current(A)
|
22+22
|
44+22
|
44+44
|
Max Operating PV Input Current(A)
|
13+13
|
26+13
|
26+26
|
No.of MPP Trackers/No.of String Per MPP Tracker
|
2/1+1
|
2/2+1
|
2/2+2
|
AC Input/Output Data
|
|
Rated AC Input/Output Active Power(W)
|
5000
|
6000
|
7600
|
8000
|
Max AC Input/Output Apparent Power (VA)
|
5500
|
6600
|
8360
|
8800
|
Peak Power (off-grid)(W)
|
2 times of rated power,10s
|
Rated AC Input/Output Current(A)
|
20.8
|
25
|
31.7
|
33.3
|
Max AC Input/Output Current(A)
|
22.9
|
27.5
|
34.8
|
36.7
|
Max Continuous AC Passthrough (grid to load)(A)
|
40
|
50
|
Rated Input/Output Voltage/Range(V)
|
120/240;208 0.88Un<U<1.1Un
|
Grid Connection Form
|
2L+N+PE
|
Rated Input/Output Grid Frequency/Range
|
60Hz/55Hz-65Hz
|
Power Factor Adjustment Range
|
0.9-1
|
Total Current Harmonic Distortion THDi
|
<3% (of nominal power)
|
DC Injection Current
|
<0.5%ln
|
Efficiency
|
|
Max Efficiency
|
97.6%
|
Euro Efficiency
|
96.5%
|
MPPT Efficiency
|
>99%
|
Equipment Protection
|
|
DC Polarity Reverse Connection Protection
|
yes
|
AC Output Overcurrent Protection
|
yes
|
AC Output Overvoltage Protection
|
yes
|
AC Output Short Circuit Protection
|
yes
|
Thermal Protection
|
yes
|
DC Terminal Insulation Impedance Monitoring
|
yes
|
DC Component Monitoring
|
yes
|
Ground Fault Current Monitoring
|
yes
|
Power Network Monitoring
|
yes
|
Island Protection Monitoring
|
yes
|
Earth Fault Detection
|
yes
|
DC Input Switch
|
yes
|
Overvoltage Load Drop Protection
|
yes
|
Residual Current (RCD) Detection
|
yes
|
Surge Protection Level
|
TYPE II(DC),TYPE II(AC)
|
Interface
|
|
Communication Interface
|
WIFI, RS485, CAN
|
General Data
|
|
Operating Temperature Range
|
-40 to +60℃
, >45℃
Derating
|
Permissible Ambient Humidity
|
0~100%
|
Permissible Altitude
|
2000m
|
Noise
|
<30 dB(A)
|
Ingress Protection(IP) Rating
|
TYPE3R
|
Inverter Topology
|
Non-Isolated
|
Over Voltage Category
|
OVC II(DC),OVC IV(AC)
|
Cabinet size(W*H*D)[mm]
|
420×670×233(Excluding connectors and brackets)
|
Weight[kg]
|
30
|
Warranty
|
5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
|
Type Of Cooling
|
Intelligent air cooling
|
Grid Regulation
|
EN 50549,UNE 217002,NRS 097,IEEE 1547.1,SRD V2.0
|
Safety EMC/Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2,FCC,UL 1741
|